30KVA Vertiv ITA2 UPS Indoor Power Cabinet
The Vertiv ITA2 UPS Indoor Power Cabinet is a fully digital, highly reliable, double-conversion UPS solution that provides clean and consistent power.
- Product Introduction
The Vertiv ITA2 UPS Indoor Power Cabinet is a fully digital, highly reliable, double-conversion UPS solution that provides clean and consistent power. This highly efficient solution is ideal for various deployments, including IT racks, network closets, automation control systems, and precision instruments to small-sized control rooms among other edge applications.
1. Cutting–edge design enables seamless integration into various ecosystems
2. Tailored for global deployment in a low-carbon, compact footprint
The ultimate level of engineering and dynamics that have gone beyond the development of this innovative, next-generation product facilitates top-notch availability and excellent performance at low ownership costs, giving you the ultimate peace of mind.
Application Areas
1) Edge Networks
2) Data Centers
3) Automation industries
4) Server Farms
5) Workstations
6) Telecom
Vertiv ITA2 UPS Indoor Power Cabinet offers best-in-class efficiency of up to 96.5% in double conversion mode over a wide range of load conditions, resulting in significant OPEX cost savings. Vertiv ITA2 UPS Indoor Power Cabinet integrated Smart Sleep technology in ECO mode provides a superlative efficiency of up to 99%.
The Most Flexible UPS
Optimized modules minimize the amount of used space in the rack
The support base makes it convenient and stable to place on a floor
Adjustable display panel ensures readability and ease of use
Configuration easily extends to batteries and POD cabinet
Available in different wattage variations, the Vertiv ITA2 UPS Indoor Power Cabinet is ideal in the edge of networks, light industrial applications, and data centers, easily blending into any virtualized environment and providing comprehensive power protection at reduced operating costs.
Reliability in a compact footprint
Fully digital control with high output voltage precision
Manages all the nine power problems including sagging, spikes, and fluctuations
Built-in intelligent communication card for remote monitoring and management
Built-in-power charger for fast charging reduces the battery charging time
Prolonged backup time through cascaded connection
Quality-tested for 1000 hours for extreme durability and tolerance even in stringent conditions
High Availability
Early Warning of UPS System Status
Multiple audible and visual alarms instantly alert for critical issues.
Periodic Battery Testing
Provides automatic and manual self-diagnostic battery testing for peace of mind.
Power-Factor Correction
Prevents noise, harmonics, and distortion from being transferred to connected loads or fed back to the utility.
Lightning and Surge Protection
The transient voltage surge suppression circuitry inside the Liebert® ITA2™ provides additional protection for the connected equipment.
Wide Input Voltage Window
Prolong battery life by allowing the UPS to maximize the use of utility power before being transferred to the battery when the input voltage exceeds the specified limits.
Technical Specifications
|
Nominal Ratings (kVA) Long Backup Model |
5 |
6 |
10 |
16 |
20 |
30 |
|
ITA-05k00AL1102P00 |
ITA-06k00AL1102P00 |
ITA-10k00ALA102P00 |
ITA-16k00AL3A02P00 |
ITA-20k00AL3A02P00 |
ITA-30k00AL3302P00 |
Input Parameters
|
Nominal Input Voltage (V) |
220/230/240VAC 1-Phase, 2 Wire |
220/230/240VAC 1-Phase, 2 Wire 380/400/415VAC 3-Phase, 4 Wire |
380/400/415VAC 3-Phase, 4 Wire |
|
Input Voltage Range (V) |
176-288VAC at full load; 100-176VAC at linear derating; 100VAC at half load |
||
|
Nominal Input Frequency (Hz) |
50/60 |
||
|
Input Frequency Range (Hz) |
40-70 |
||
|
Input Power Factor (kW/kVA)* |
0.99 |
||
|
Current THD at full linear load (THDi%)* |
<3 |
||
Battery
|
Battery Blocks Per String |
12*, 15, 16, 17, 18, 19, 20 24*, 30, 32, 34, 36, 38, 40 32, 34, 36, 38, 40 |
|||
|
Battery Charger Max. Power (A) |
= 5A |
= 8A |
= 13A |
|
|
Battery Option |
P/C : ITA-BCI0020K01 ( built-in battery module of 16 block X 12V X 9AH) Battery cabinet Dimensions in rack arrangement - 430(W) x 739(D) x 85(H) |
Only external battery cabinet |
||
Output
|
Nominal Output Voltage (V) |
220/230/240 (1-phase) |
220/230/240VAC (1-Phase), 380/400/415VAC (3-Phase) |
380/400/415VAC (3-Phase) |
|
Nominal Output Frequency (Hz) |
50/60 |
||
|
Rated Power Factor (kW/kVA) |
Unity |
||
|
Voltage Harmonic Distortion (%) |
<2% for Linear loads & <5% for Non-linear loads |
||
|
Overload Capacity |
At 25°C: 105% ~ 125%, 5min; 125% ~ 150%, 1min; 150%, 200ms |
||
|
Crest Factor |
3:1 |
||
Efficiency
|
Online Mode Efficiency |
Up to 95.5% |
Up to 95.8% |
Up to 96.2% |
Up to 96.5% |
|
ECO Mode Efficiency |
Up to 99% |
|||
Dimensions and Weight
|
Dimensions (W x D x H) in mm Rack Mounted Arrangement |
430x450x85 |
430x560x85 |
430x570x130 |
|
|
Weight (kg) |
11 |
15 |
23 |
23.5 |
General
|
Nosie at 1 m (dBA) |
=55 |
=58 |
<60 |
|
Operating Temperature (°C) |
0 ~ 50* |
||
|
Relative Humidity (%RH) |
5 ~ 95, non-condensing |
||
|
Altitude (m) |
=3000m |
||
|
General and Safety Requirements for UPS |
IEC/EN 62040-1 |
||
|
EMC Requirements for UPS |
IEC/EN 62040-2 |
||
|
UPS Classification According to IEC 62040-3 |
VFI-SS-111 |
||
Hot Tags: 30kva vertiv ita2 ups indoor power cabinet, China 30kva vertiv ita2 ups indoor power cabinet manufacturers, suppliers, factory, system embedded power supply 48V 120A, vertiv r48 3000e3, 60KVA online UPS, industrial UPS, Power System 4U 200A, 48V 5800W Emerson R48 5800A Rectifier Module