Radiating Leaky Cable HLRCTCYZ-50-32H(1-1/4″)

Radiating Leaky Cable HLRCTCYZ-50-32H(1-1/4″)

Fire Retardant Cable
FRNC HLRCTCYZ-50-32H
With the broadband capability of 700-2700MHz.

  • Product Introduction

Cables Model

 

 

Fire Retardant Cable
FRNC HLRCTCYZ-50-32H
With the broadband capability of 700-2700MHz.

 

Mechanical Specifications

 

 

Inner Conductor Smooth Copper Tube 13.1mm
Dielectric Foamed Polyethylene 33.0mm
Outer Conductor Slotted And Corrugated Copper Tape
Jacket FRNC 38.0mm
Minimum Bending Radius,Single 400mm
Tensile Strength 2000N
Permissible Temperature Range,Installation -25℃~+60℃
Permissible Temperature Range,Operation -40℃~+80℃
Permissible Temperature Range,Storage -40℃~+80℃

 

Environmental Characteristics

 

 

Environmental Protection RoHs

 

Electrical Characteristics

 

 

Impedance 50Ω±2Ω
Max Operating Frequency 2700MHz
VSWR(Operating Frequency) ≤1.30
Velocity 88%
Capacitance 76pF/m
Insulation Resistance 5000MΩ·km
DC-Resistance Inner Conductor 1.0Ω/km
DC-Resistance Outer Conductor 3.0Ω/km
DC Test Voltage 10000V
Jacket Spark Test Voltage 10000V

 

Attenuation and Coupling Loss

 

 

Frequency Attenuation @20℃ Coupling Loss 2m
MHz dB/100m dB(50%/95%)
700 2.3 76/82
800 2.7 71/78
900 3.1 69/73
1800 5.0 66/72
1900 5.6 62/68
2000 5.8 67/72
2200 6.2 66/72
2400 7.8 64/71
2600 8.0 69/76
Tolerance Of Attenuation:≤1.10×
Tolerance Of Coupling Loss:±10dB
Test conditions: When measuring attenuation, the ambient temperature is 20 ℃; When measuring coupling loss, the ambient temperature is 20 ℃.
The VSWR of the above tested cables is 1.0

Hot Tags: radiating leaky cable hlrctcyz-50-32h(1-1/4″), China radiating leaky cable hlrctcyz-50-32h(1-1/4″) manufacturers, suppliers, factory, industrial UPS, Vertiv Liebert GXE2 Uninterrupted Power Supply ups 6 20KVA Online UPS, 30KVA UPS Indoor Power Cabinet, precision air conditioner fresh air handling unit, dc power system, 120VA Rack UPS