Foam Cable HCAAY(YZ)-50-12(1/2")
Standard Cable
PE Jacket HCAAY-50-12
Fire Retardant Cable
Fire-Retardant Jacket HCAAYZ-50-12
- Product Introduction
Cables Model
Standard Cable
1/2" PE Jacket HCAAY-50-12
Fire Retardant Cable
1/2" Fire-Retardant Jacket HCAAYZ-50-12
Mechanical Specifications
| Inner Conductor | CCA |
4.8mm |
| Insulation | Physical Foam Polyethylene |
12.2mm |
| Outer Conductor | Ring Copper Tube |
13.8mm |
|
Jacket |
PE |
15.9mm |
|
(FRNC) |
(15.9mm) |
|
| Minimum Bending Radius(Single Bend) |
80mm |
|
| Minimum Bending Radius(Repeated Bends) |
125mm |
|
| Minimum Number Of Bends(Typical) |
15 |
|
|
Tensile Strength |
1130N |
|
|
Installation Temperature |
PE |
-20℃~60℃ |
|
(FRNC) |
-20℃~60℃ |
|
|
Storage Temperature |
PE |
-40℃~70℃ |
|
(FRNC) |
-25℃~80℃ |
|
Electrical Characteristics
|
Impedance |
50Ω±1 Ω |
|
|
Maximum Frequence |
8.8GHz |
|
|
Cut-Off Frequency |
10.0GHz |
|
|
Velocity Ratio |
88% |
|
|
Peak Power |
40kW |
|
|
Insulation Resistance |
≥10000MΩ·kM |
|
|
DC Breakdown Voltage |
6000V |
|
|
Nominal Capacitance |
76pF/m |
|
|
Inductance |
0.19μH/m |
|
|
(VSWR) |
400MHz~500MHz |
≤1.10 |
|
800MHz~1000MHz |
≤1.10 |
|
|
1700MHz~2200MHz |
≤1.10 |
|
|
0MHz~3000MHz |
≤1.15 |
|
|
3000MHz~4000MHz |
≤1.20 |
|
|
4000MHz~6000MHz |
≤1.28 |
|
Attenuation And Coupling Loss
|
Frequency |
Attenuation |
Average Power |
|
MHz |
dB/100m |
kW |
|
0.5 |
0.148 |
40.0 |
|
1 |
0.209 |
35.8 |
|
1.5 |
0.256 |
29.2 |
|
2 |
0.296 |
25.3 |
|
10 |
0.665 |
11.3 |
|
20 |
0.945 |
7.93 |
|
30 |
1.158 |
6.46 |
|
50 |
1.505 |
4.98 |
|
87 |
2.010 |
3.73 |
|
100 |
2.149 |
3.49 |
|
108 |
2.238 |
3.36 |
|
150 |
2.614 |
2.75 |
|
174 |
2.861 |
2.62 |
|
200 |
3.079 |
2.44 |
|
300 |
3.792 |
1.97 |
|
400 |
4.416 |
1.70 |
|
450 |
4.683 |
1.53 |
|
500 |
4.970 |
1.51 |
|
512 |
5.030 |
1.49 |
|
600 |
5.475 |
1.37 |
|
700 |
5.950 |
1.26 |
|
800 |
6.396 |
1.17 |
|
824 |
6.495 |
1.15 |
|
900 |
6.822 |
1.05 |
|
960 |
7.050 |
1.04 |
|
1000 |
7.208 |
1.02 |
|
1250 |
8.149 |
0.921 |
|
1500 |
9.000 |
0.833 |
|
1700 |
9.644 |
0.777 |
|
1800 |
10.099 |
0.723 |
|
2000 |
10.693 |
0.673 |
|
2100 |
10.990 |
0.653 |
|
2200 |
11.089 |
0.615 |
|
2400 |
11.733 |
0.608 |
|
3000 |
13.218 |
0.563 |
|
4000 |
15.644 |
0.479 |
|
6000 |
19.901 |
0.378 |
|
8000 |
23.564 |
0.318 |
Test conditions: When measuring attenuation, the ambient temperature is 20 ℃; When measuring the average power, the ambient temperature is 40 ℃ and the internal conductor temperature is 100 ℃; The VSWR of the above tested cables is 1.0
Hot Tags: foam cable hcaay(yz)-50-12(1/2"), China foam cable hcaay(yz)-50-12(1/2") manufacturers, suppliers, factory, High Heat Precision air conditioner, Vertiv Network Power Supply Rectifier R48 3200E, NetSure 731 A61 S4 Vertiv DC Power System, Liebert XD High Heat Density Precision Air Conditioner, S series multi scenario UPS systems, fluorine pump precision air conditioner